Raptor Tank Gauging
PRODUCTS & SOLUTIONS
2410 Tank Hub
-
Handles data communication between field devices and the control room.
-
Feeds power to Rosemount Field Devices on the FISCO compliant intrinsically safe Tankbus
-
Calculate average temperature, observed density and strapping table based volume
-
Get two configurable output relays, ad one anaolog output for level alaram, all of which are SIL certified
5900S Radar Level Gauge
-
Accuracy: ± 0.5 mm (± 0.020 in)
-
Stability: Typically < ± 0.5 mm (0.020 in) in -40 to +158 °F
-
Update Rate: New Measurement every 0.3 second.
-
Increased Safety with 3rd party certified IEC 61508 SIL 2 or SIL 3 capability
-
Convenient and safe installation with 2-wire IS bus power supply
-
Measure in all bulk storage tank types and products, ranging from liquefied gases, light products, crude oil and bitumen
5900C Radar Level Gauge
-
Accuracy: ± 2 mm (± 0.08 in)
-
Stability: Typically < ± 0.5 mm (0.020 in) in -40 to +158 °F
-
Update Rate: New Measurement every 0.3 second.
-
Increased Safety with 3rd party certified IEC 61508 SIL 2 or SIL 3 capability
-
Possible to integrate with legacy tank gauging systems
-
Measure in all bulk storage tank types and products, ranging from liquefied gases, light products, crude oil and bitumen
-
Include wired and/or wireless data transmission
Parabolic Antenna
-
Best choice in tanks without still-pipe
-
Demanding Environments with sticky or condensing liquids
-
Antenna design gives extreme tolerance to product build-up and condensation
-
Measures all products ranging from light products to heavy fuel oil, bitumen and asphalt
-
Installation normally with tank in serviceIn certain cases, it can be used on tanks with floating roofs to measure the distance down to a target plate on the floating roof.
Still Pipe Array Antenna
-
Best choice in tanks with still-pipe
-
Demanding Environments with sticky or condensing liquids
-
Antenna design gives extreme tolerance to product build-up and condensation
-
Hinged hatch version enables easier product sampling and hand-dips on same gauge pole as radar
-
Measures all products ranging from light products to heavy fuel oil, bitumen and asphalt
-
Installation normally with tank in service. In certain cases, it can be used on tanks with floating roofs to measure the distance down to a target plate on the floating roof.
LPG/LNG Antenna
-
Best choice for pressurized or cryogenic liquefied gas
-
Strong echo even under surface boiling conditions
-
Measurement verification with closed tank via reference device (See Datasheet Below)
-
Installation is made with the pressurized tank taken out of service
-
Built-in pressure sensor for vapor compensation gives best measurement performance
Horn/Cone Antenna
-
Designed for easy installation on fixed roof tanks, with smaller nozzles
-
Nozzles from 4 in. to 8in.
-
Communicates via a 2-wire, Intrinsically safe Tankbus for easy and safe installation
-
Measures on a variety of products except asphalt or similar for which the parabolic is recommended
2240S Multi-Input Temperature Transmitter
-
Ultra-stable temperature measurement for precise inventory calculations and custody transfer for API chapter 7.3 compliance
-
Obtain outstanding temperature conversion accuracy of ±0.05 °C (±0.09 °F)
-
Connect up to 16 four-wire temperature elements
-
Include Integreated water level sensor
-
Two-Wire IS bus power supply
644 Single Spot Temperature Transmitter
-
Dual and single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)
-
Output Signal: 4-20 mA /HART® protocol, FOUNDATION™ fieldbus protocol, PROFIBUS® PA protocol
-
Display/Interface: LCD Display or LCD Display with Local Operator Interface (LOI)
-
Calibration Options: Transmitter-sensor matching (Callendar-Van Dusen constants), 5-point calibration
3051S Coplanar
Pressure Transmitter
-
Use it in all storage applications, including crude oil tanks, pressurized tanks, and tanks with/without floating roofs
-
Measure with industry leading 0.025% pressure accuracy and density according to API chapter 3.6
-
Enable online mass and density calculation - no need for manual density sampling
-
Benefit from convenient and safe installation with two-wire IS bus power supply